6.9 Assembly

To assemble the pump consult the sectional

drawings, see section 8,

Parts list and drawings

.

Ensure threads, gasket and O-ring mating faces are

clean. Apply thread sealant to non-face sealing pipe

thread fittings.

6.9.1 Bearing housing assembly - Grease

lubricated

a) Be sure the shoulders where the bearings seat,

are free of burrs and contaminants.

b) Mount the grease retainers into their respective

bores [51, 51A]. Prick punch the outer diameter

at two places 180

o

apart to secure them to the

bearing frame, if necessary. Do not remove the

grease retainers on disassembly unless they are

to be replaced.

c) Mount the bearing cups (outer races) [16,18] into

their respective bearing housing bores (either

chill or press in to install). Be sure the cups seat

against the bearing housing shoulders.

d) Assemble the line bearing cone [16] on the shaft

[6] (heat or press to install). See section 6.7.3 for

details.

e) Install the shaft [6] with the thoroughly grease-

packed line bearing cone fitted, through the

housing and support the assembly vertically

(thrust end up).

f) Heat the thrust-bearing cone to approximately

95

o

C (200

o

F) and assemble it on the shaft

together with the bearing washer [22B], lock

washer [22A], and locknut [22]. Hand tighten the

nut.

g) Assemble the line bearing inner seal [40A], line

bearing cover [35] and outer seal [40A]. Adjust

the bearing endplay; See Bearing End Play

adjustment in section 6.7.4.

h) Pack the thrust bearing [18] with grease.

i) Install the thrust bearing’s inside seal [49], cover

[37] and outside seal [40].

The impeller set screw and wearing ring

screws are locked in place using Loctite 271 or

equivalent. The shaft sleeve is mounted using

Loctite RC/680 or equivalent. Mating surfaces must

be thoroughly cleaned and dry prior to application of

the adhesive compound.

6.9.1.1 Impeller nut

IMPELLER NUT

FILLET

(2 PLACES 18O°APART)

IMPELLER NUT

LOCATION FOR

SQUARE BAR

IMPELLER NUT

SET SCREW

Grease all the contact seal lips before

installation. Position the outside seals (line and thrust

bearing) with minimum lip contact to the covers.

Excessive lip pressure will result in the seal rings

running hot and premature seal ring failure.

6.9.2 Pump assembly

To assemble the pump, reverse the dismantling

instructions previously described.

a) Follow the bearing housing assembly, wearing

ring, packing, and shaft sleeve assembly

instructions. Torque all assembly bolts and

screws to the recommended torque values listed

in section 6.5.

b) If the unit is equipped with a mechanical seal,

refer to the mechanical seal manufacturer's

instructions for installation.

c) Install the rotating assembly in the casing [1].

d) Check that the impeller [2] turns freely and adjust

the wearing ring gap. See section 6.1.6 for

details.

e) Align the pump with the motor; see Section 4.5.

f) Install the packing and seal cage; see Section

6.1.8.

g) Add lubricant as described in Section 5.2.