Check that the sleeve is free of pits, burrs or sharp

edges to prevent cutting or improper sealing of the

rotating O-rings.

6.1.9.3 Installing the seal

Refer to the manufacturer's instructions for seal

installation.

6.1.9.4 Before starting the unit.

Check and make certain that the gland flushing line)

is clean (and also, return line if it is a double seal,

open and free of any obstruction that may interfere

with circulation of clear flushing liquid for the seal.

Before start up bleed all air from the seal cavity. This

is necessary to ensure a clean liquid environment for

effective seal operation

6.1.10 Re-lubrication

Lubricant and bearing temperature analysis can be

useful in optimizing lubricant change intervals. In

general the following is recommended.

6.1.10.1 Oil lubrication

Maintaining the correct oil level is very

important. If a sight glass has been fitted then

regular checks should be made to ensure the level is

maintained at the center of the glass window.

Refer to section 5. for methods of oil fill, oil grade

recommendations and for the schedule and

temperature limits.

6.1.10.2 Grease lubrication

See section 5.2.5 for grease

recommendations. Re-grease via grease nipples

depending on the severity of the application.

a) It is important not to under or over grease the

bearings as this will lead to over heating and

premature failure. Grease lubricated bearing

housings have grease nipples fitted in the

bearing covers.

b) Connect grease gun to the nipple.

c) Press grease into the bearing housing until the

first signs of it appear in the gap between the

housing and shaft, then stop greasing.

d) The maximum allowable operating temperatures

for anti friction bearings will vary from unit to unit,

depending on ambient and fluid temperature.

The rise above ambient should not normally

exceed 55

°

C (131

°

F) or a combined maximum

of 95

°

C (204

°

F).

e) A continuously rising temperature or an abrupt

temperature rise indicates a problem. If these

symptoms occur, stop the pump immediately and

investigate the cause.

TIME

TE

M

P

E

R

A

TU

R

E

6.1.10.3 Grease change

if Kerosene is used to clean the

bearings make sure that the required safety

measures are to be in place while handling this liquid

fuel for cleaning (See Fuel supplier/ manufacturer’s

Material Safety Data Sheets for provided flash and

flame temperatures).

a) Remove the bearing housing from the rotor

assembly.

b) Brush the bearing housing with hot oil (at about

94

o

to 115

o

C (200

o

to 240

o

F) or other non-toxic

solvent.

c) Clean and flush out the housing with a light

mineral oil.

d) Do not use waste oil to clean the housing.