Care must be taken when adjusting the gland

on an operating pump. Safety gloves are essential.

Loose clothing must not be worn to avoid being

caught up by the pump shaft. Shaft guards must be

replaced after the gland adjustment is complete.

Never run gland packing dry, even for

a short time.

5.8.3 Pumps fitted with mechanical seal

Mechanical seals require no adjustment. Any slight

initial leakage will stop when the seal is run in.

Before pumping dirty liquids it is advisable, if

possible, to run in the pump mechanical seal using

clean liquid to safeguard the seal face.

External flush or quench should be

started before the pump is run and allowed to flow for

a period after the pump has stopped.

Never run a mechanical seal dry,

even for a short time.

5.8.4 Bearings

If the pumps are working in a potentially

explosive atmosphere, temperature or vibration

monitoring at the bearings is recommended.

If bearing temperatures are to be monitored it is

essential that a benchmark temperature is recorded

at the commissioning stage and after the bearing

temperature has stabilized.

Record the bearing temperature (t) and the

ambient temperature (ta)

Estimate the likely maximum ambient

temperature (tb)

Set the alarm at (t+tb-ta+5)

°

C [(t+tb-ta+10)

°

F]

and the trip at 100

°

C (212

°

F) for oil lubrication

and 105

°

C (220

°

F) for grease lubrication

The maximum operating temperatures for anti-friction

bearings will differ from pump to pump. In general,

bearing frames using Timken bearings can run 40

o

C

(100

o

F) or higher above ambient. This should be no

cause for alarm. However, continuously rising

temperatures, or an abrupt temperature rise, are

indicative of possible trouble. These symptoms

require immediate stopping of the pump and a

thorough investigation to determine the cause of the

trouble.

The pump bearings will show a definite temperature

rise immediately after lubrication and should be

operated for 5 to 10 hours to allow the temperature to

stabilize.

It is important, particularly with grease lubrication, to

keep a check on bearing temperatures.

After start up the temperature rise should be gradual,

reaching a maximum after approximately 1.5 to 2

hours. This temperature rise should then remain

constant or marginally reduce with time.

5.8.5 Reduced Capacity operation.

Generally, Flowserve non-clog pumps are designed

for continuous operation above 65% of the peak

efficiency capacity at maximum RPM and impeller

diameter. They are suitable for occasional or

intermittent operation at capacities outside these

limits, however, pump operation may be noisy and

component life may be reduced.

These limitations are placed because the impellers

have wide discharges and at other capacities high

magnitudes of radial reactions are encountered and

flow re-circulation may occur. This is an inherent

design characteristic for a pump of this type.

In many cases, particularly in sewage pumping

applications, reduced capacities are met by a

reduction in pump speed and no throttling is used.

Under these circumstances, these part capacity

applications are not nearly so critical because of

lower pump speed and relatively lower pump

operating heads.

Refer applications where pump operation at other

capacities are anticipated to your nearest Flowserve

Sales Representative.

5.8.6 Suction lift

Sometimes the suction conditions imposed upon a

centrifugal pump are extremely unfavorable and lead

to a complete breakdown of the pump operation.

The suction lift must be kept within the suction

limitations for which the pump was sold. If the

original operating conditions must be changed for

any reason, consult your nearest Flowserve Sales

Representative. Care should also be exercised to

keep the suction piping air tight and sealed against

leakage.