Flowserve MNV User Manual

Page 23

Advertising
background image

MNV & MNZ USER INSTRUCTIONS ENGLISH 71569188 11/04

Page 23 of 47

®

5.2.3.1 Grease fittings

PLUGGED

GREASE FITTING

GREASE FITTING

THRUST BEARING

END

BEARING

FRAME

LINE BEARING

END

PLUGGED

5.2.4 Bearing operating temperatures

The maximum operating temperatures for anti-friction

bearings will differ from unit to unit. In general,

bearing frames using Timken bearings can run 40

o

C

(100

o

F) higher above ambient. This should be no

cause for alarm. However, continuously rising

temperatures, or an abrupt temperature rise, is

indicative of possible trouble. These symptoms

require immediate stopping of the pump and a

thorough investigation to determine the cause of the

trouble.

TIME

TE

M

P

E

R

A

TU

R

E

5.2.5 Selection of grease lubricants

The bearings are to be lubricated with a premium

quality lithium based NGLI # 2 grease suitable for

antifriction bearing use. The grease should have a

viscosity range of 150 to 220 cSt (mm

2

/sec) at 40

o

C

(100

o

F) and Timken load rating of 16 kg (35 lb.)

minimum. The grease should contain rust and

oxidation inhibitors and extreme pressure additives

Others greases meeting the above requirements may

also be used.

5.2.5.1 Recommended grease lubricants

AMOCO

AMOLITH EP2

CHEVRON

DURALITH EP2

EXXON

LIDOK EP2

MOBIL

MOBILUX EP2

BP

ENERGREASE-LS-EP2

SHELL

ALVANIA EP2

TEXACO

MULTIFAK EP2

Advertising
This manual is related to the following products:

MNZ, MNF, MNC