3 impeller clearance, 4 direction of rotation – Flowserve MNV User Manual

Page 24

Advertising
background image

MNV & MNZ USER INSTRUCTIONS ENGLISH 71569188 11/04

Page 24 of 47

®

5.2.5.2 Recommended grease fill quantities

Frame

No.

Line

Bearing,

Timken

CUP P.N./

CONE P.N.

Thrust

Bearing,

Timken

CUP P.N./

CONE P.N.

Initial Fill

g

(oz)

Suggested Re-Lubrication

g

(oz)

Line Bearing

Thrust Bearing

Freq.

Qty. Ounces

Conn.

1

Cover

2

Conn.

1

Cover

2

Hours

Line Brg

Thr. Brg

4T

JLM506849/

JLM506810

M804048/

M804010

43

(1.5)

9

(0.3)

28

(1.0)

23

(0.8)

300

9

(0.3)

9

(0.3)

5T

29685/

29620

72225C/

72487

56

(2.0)

14

(0.5)

56

(2.0)

56

(2.0)

300

11

(0.4)

11

(0.4)

6

6536/

6580

6536/

6580

369

(13.0)

114

(0.4)

369

(13.0)

225

(8.0)

300

28

(1.0)

28

(1.0)

6A

HM218210/

HM218248

9220/

9285

3

56

(2.0)

42

(1.5)

85

(3.0)

127

(4.6)

300

14

(0.5)

14

(0.5)

7L

JM822010/

JM822049

9321/

9386H

595

(21.0)

85

(3.0)

370

(13.0)

255

(9.0)

300

28

(1.0)

28

(1.0)

7H

JHM522610/

JHM522649

98788/

98400

480

(17.0)

225

(8.0)

565

(20.0)

650

(23.0)

300

28

(1.0)

42

(1.5)

8L

74850/

74500

HM926710/

HM926740

990

(35.0)

200

(7.0)

680

(24.0)

310

(11.0)

500

42

(1.5)

42

(1.5)

8H

95925/

95500

HH926710/

HH926749

880

(31.0)

425

(15.0)

1135

(40.0)

1135

(40.0)

500

56

(2.0)

56

(2.0)

8HA

82931/

82576

HH926710/

HH926749

880

(31.0)

625

(22.0)

1135

(40.0)

1135

(40.0)

500

56

(2.0)

56

(2.0)

9H

H239610/

H239640

H936310/

H936349

1560

(55.0)

625

(22.0)

1845

(65.0)

1700

(60.0)

500

70

(2.5)

70

(2.5)

9HA

93125/

93825

H936310/

H936349

1560

(55.0)

480

(17.0)

1845

(65.0)

1700

(60.0)

500

70

(2.5)

70

(2.5)

This value indicates the amount of grease to be added to the bearing through the grease connection.

For horizontal units, the space between the bearing and the grease retainer will be 2/3 full.

This value indicates the amount of grease required for packing the space between each bearing and its

respective cover. The space between bearings and their respective covers should be 1/3 full.

This bearing must comply to Timken Co. inspection code 20481

5.2.6 Grease change schedule

When grease nipples are fitted, one charge between

grease changes is advisable for most operating

conditions.

The characteristics of the installation and severity of

service will determine the frequency of lubrication.

Lubricant and bearing temperature analysis can be

useful in optimizing lubricant change intervals.

The bearing temperature may be allowed to rise to 40

ºC (100 ºF) above ambient. If the temperature is

exceeding this limit, a special consideration may have

to be given to set the alarm and trip. Consult

Flowserve with the temperature data for

recommendations (If needed).

Never mix greases containing different

bases, thickeners or additives.

5.3 Impeller clearance

(See section 6.1.6)

5.4 Direction of rotation

Ensure the pump is given the same

rotation as the pump direction arrow cast on the

pump casing.

To avoid dry running the pump must either be filled

with liquid or have the flexible coupling disconnected

before driver is switched on.

If maintenance work has been carried

out to the site's electricity supply, the direction of

rotation should be re-checked as above in case the

supply phasing has been altered.

Advertising
This manual is related to the following products:

MNZ, MNF, MNC