MNV & MNZ USER INSTRUCTIONS ENGLISH 71569188 11/04

Page 9 of 47

®

1.8 Noise level

Whenever pump noise level exceeds 85 dBA, attention must be given to prevailing Health and Safety

Legislation, to limit the exposure of plant operating personnel to the noise. Typical safety level requires to limit

the sound level of 90 dBA for 8 hours of exposure and the allowable dBA value increases 5 dBA for each

halving of exposure time. The usual approach is to control exposure time to the noise or to enclose the

machine to reduce emitted sound.

You may have already specified a limiting noise level when the equipment was ordered, however if no noise

requirements were defined then machines above a certain power level will exceed 85 dBA. In such situations,

consideration must be given to the fitting of an acoustic enclosure to meet local regulations.

1.8.1 Typical sound levels for MNV & MNZ pumps

Typical sound pressure levels measured in dB, and are A-weighted.

Motor

Frame

Size.

NEMA

RPM

Motor Only

Sound

Pressure

(dBA )

Pump only

Sound

Pressure

(dBA )

Combination

of pump and

motor

Sound

pressure

(dBA)

1800

60.0

65

70

180

1200 & slower

55.0

55

63

1800

60.0

65

69

210

1200 & slower

55.0

56

63

1800

70.0

77

77

250

1200 & slower

60.0

68

69

1800

70.0

77

77

280

1200 & slower

60.0

68

69

1800

65.0

77

77

320

1200 & slower

65.0

69

69

1800

65.0

77

78

360

1200 & slower

65.0

68

69

1800

70.0

77

78

400

1200 & slower

65.0

68

69

1800

70.0

77

78

440

1200 & slower

65

68

69

Sound pressure values indicated for the motor are extracted from typical motor manufacturer’s data at no load

conditions and are not guaranteed. They may vary depending on the type of motor, enclosure used, and the

manufacturer. The sound pressure values for the pump are estimated levels in free field measured 1 meter from the

nearest major pump surface and at a height of 1.5 meters above the floor. using speed, flow rate, motor horsepower,

number of impeller vanes, and other variables. Therefore values indicated are for reference only and could exceed

the estimated values by as much as 8~10 dBA depending upon factors such as installed conditions, building

acoustics, foundation, piping, operating conditions, surrounding machinery. It is highly recommended to take actual

field measurement of sound pressure values, apply enclosures and safety measures mandated by the local

authorities and prevailing safety regulations. For all other pump and motor frame size combinations, the sound

levels have to measured and safety measures have to be adopted.

For units driven by equipment other than electric motors or units contained within enclosures, see the

accompanying information sheets and manuals.