Lead V6 .............................................................. 80 %

Normal Sinus Rhythm ............................................. 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 Universal ECG

Jacks, color-coded to AHA and IEC Standards.

Amplitude ................................................................. 0.05 mV to 0.45 mV (0.05 mV steps), 0.5 mV to 5.5 mV (0.5 mV steps)

Amplitude Accuracy ................................................

±

2 % of setting Lead II. All other leads

±

5 %

ECG Rate .................................................................. 30, 40, 45, 60, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, and 300 BPM

Rate Accuracy ..........................................................

±

1 % of setting

ECG Waveform Selection ........................................ Adult (80 ms) or pediatric (40 ms) QRS duration

Artifact (Superimposed) .......................................... 50 and 60 Hz, muscle, baseline wander, respiration

ST-Segment Elevation ............................................. Adult mode only. -0.8 mV to +0.8 mV (0.1 mV steps) Additional steps: +0.05 mV and -0.05 mV

Power-On Default ..................................................... 80 BPM, 1.0 mV, adult QRS, ST-segment elevation of 0 mV, and a P-R interval of 0.16 seconds

Pacemaker Waveform

Pacer-Pulse Amplitude ............................................ 0 (off), 1, 2, 5, 10 mV

±

10 % for lead II (reference lead) with other leads proportional as for performance

waves.

Pacer-Pulse Width ................................................... 0.1, 0.5, 1.0, 1.5, 2.0 ms

±

5 %

Pacing Rate .............................................................. 75 BPM

Paced Arrhythmias .................................................. Atrial 80 BPM

Asynchronous 75 BPM
Demand with frequent sinus beats
Demand with occasional sinus beats
Atrio-Ventricular sequential
Noncapture (one time)
Nonfunction

Power-On Default ..................................................... Off

Arrhythmia

Baseline NSR ........................................................... 80 BPM

PVC Focus ................................................................ Left focus, standard timing (except where specified)

Supraventricular Arrhythmia .................................. Atrial fibrillation (coarse or fine), atrial flutter, sinus arrhythmia, missed beat (one time), atrial tachycardia,

paroxysmal atrial tachycardia, nodal rhythm, and supraventricular tachycardia

Premature Arrhythmia ............................................. (All one-time events) Premature atrial contraction (PAC), premature nodal contraction (PNC), PVC1 left

ventricular, PVC1 left ventricular – early, PVC1 left ventricular – R on T, PVC2 right ventricular, PVC2
right ventricular – early, PVC2 right ventricular – R on T, and multifocal PVCs