Fsr t, Table box, Installation & safety manual – FSR T3U Series User Manual

Page 2

Advertising
background image

FSR

T

3

U

Operations Safety Manual [

Page 2 of 5

]

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

FSR T

3

U

Table Box

INSTALLATION & SAFETY MANUAL


1. Introduction


The T3U Table Box combines elegant styling and rugged design to balance form and function.
Solid construction and ease of installation make this compact table box a compliment to any conference
room or office environment.

2. Mounting Procedure

The T3U is mounted to the underside of the table using provided cap screws. A drawing is provided for
cutting the table opening (Fig. 1). Consideration should be given to placement and position to ensure the
most functional orientation and user convenience. Table thickness range is ¾" to 2¾" maximum.

 Determine T3U location and cut opening on table (Fig 1).

 Insert T3U assembly into table opening.

 Install clamp bracket and secure T3U assembly to table by screwing cap screws to underside of table

(Fig 2). Customer to provide KO slug/penny/other flat piece for screw end, with soft table wood.

 Make electrical connections as required. Slots are provided on the cable access plate for anchoring

tie wraps to secure cable entry.


 The exposed surfaces can be cleaned using a mild household cleaner. The T3U door is opened by

applying slight pressure to the area labeled "PRESS HERE". This will expose the connector panel
area for use.


3. Installation of Low Voltage Access Panels

The T3U is offered with a verity of blank plates or pre-punched faceplates providing maximum flexibility,
and satisfying most field requirements. Standard snap in connectors, cable pass through and connector
mounting plates can be installed to suit the specific installations.

Refer to the individual options installation drawings for installation particulars.

** CAUTION ** To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.

4. Electrical Connections


There is a factory installed duplex outlet provided for local 117 VAC power at the T3U faceplate. The 8’
AC cord can be plugged into a 117 VAC outlet close to the T3U housing.

The T3U's power cord is the main-disconnect device. The power socket / outlet should be installed near
the table box and should be easily accessible. The T3U's are designed to operate in a maximum
recommended ambient temperature (TMRA) of 45° C (113° F).

For Pluggable Equipment, the socket outlet shall be installed near the equipment and shall be accessible.