Environmental and Reliability Specifications

Recommended environmental conditions for the operation are temperature
range of 50°– 104°F (10°C– 40°C), non-condensing humidity levels of 10%–
80%, and altitude ceiling of 9,840 feet (3,000 meters).

Environmental limits for transportation are temperature range of -13°– 122°F
(-25°C– 60°C), non-condensing humidity levels of 5%– 95%, and altitude
ceiling of 49,200 feet (15,000 meters)

Environmental limits for storage are established at temperature range of
-13°– 122°F (-20°C– 45°C), non-condensing humidity levels of 5%– 95%, and
altitude ceiling of 9,840 feet (3,000 meters)

The DV-WPHXT-1ctx is expected to function for more than 50,000 hours of
use at a 90% confidence level. The device is tested according to the identical
standards for testing LCD monitors.