Typical rs-232 device interconnections – FSR IT-VCM User Manual

Page 10

Advertising
background image

10










HOST COMPUTER

DTE DEVICE

DB-9 MALE

PIN

NAME

2

TxD (OUTPUT)

3

RxD (INPUT)

5

GROUND

DCE DEVICE

DB-9 FEMALE

PIN

NAME

2

TxD (INPUT)

3

RxD (OUTPUT)

5

GROUND

IT-VCM MODULE

3 PIN TERMINALS

SERIAL IN

SERIAL OUT

NAME

DIRECTION

NAME

DIRECTION

Rx

INPUT

Tx

OUTPUT

Tx

OUTPUT

Rx

INPUT

GROUND

GROUND

ADDITIONAL INTELLITOOLS MODULES

3 PIN TERMINALS

SERIAL IN

SERIAL OUT

NAME

DIRECTION

NAME

DIRECTION

Rx

INPUT

Tx

OUTPUT

Tx

OUTPUT

Rx

INPUT

GROUND

GROUND

Typical RS-232 Device Interconnections


The table below shows the typical hookup for RS-232 control of the IT-VCM module. Connections for
loopthrough applications are included.

The Serial-In port is configured for 38,400 baud, 8 data bits, 1 stop bit, and no handshaking. Serial-In
configuration cannot be changed. The Serial Output baud rate can be changed via the Serial 2 baud rate
request “SBA”.

Information on RS-232 protocol is detailed in the serial protocol manual included.