FSR MAS-3200 User Manual
Page 15

MAS-3200
15
RS-232 REMOTE CONTROL PROTOCOL
RS-232 TRANSMISSION FORMAT
Baud Rate:
9600 bps
Data Bit:
8 bits
Parity:
none
Stop Bit:
1 bit
Note - The connection between the video scaler and the remote controller requires an RS-232 modem
cable
Video Scaler
Remote Controller
PIN Definition
PIN Definition
1 NC
1 NC
2 TxD
2 RxD
3 RxD
3 TxD
4 NC
4 NC
5 GND
5 GND
6 NC
6 NC
7 NC
7 NC
8 NC
8 NC
9 NC
9 NC
RS-232 COMMAND CODES
The command and Response codes are a combination of 3 bytes. The first and second bytes are text and
the third byte is a HEX value. No carraige return is necessary.
Remote Controller Command Codes
Code Comment
‘PW’+0 power off (standby)
‘PW’+1 POWER power on (normal)
‘IN’+0 Composite video
‘IN’+1 S video
‘IN’+2 Not Used
‘IN’+3 INPUT PC bypass
‘OU’+0 VGA
‘OU’+1 480p
‘OU’+2 SVGA
‘OU’+3 XGA
‘OU’+4 SXGA
‘OU’+5 576p
‘OU’+6 720p
‘OU’+7 OUTPUT 1080i
‘OS’+0 OSD osd OFF
‘OS’+1 osd ON
‘DI’+0 display OFF
‘DI’+1 DISPLAY display ON