Final assembly – GAI-Tronics 234L(x)-xxx LITE Series Stanchions User Manual

Page 16

Advertising
background image

Pub. 42004-393B

Model 234L(x)-xxx LITE Series Stanchion

Page: 15 of 18

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-393b.doc
03/07

Final Assembly

Test the stanchion as follows:

1. Energize the circuit for testing purposes before closing the stanchion.

2. When energized, the courtesy light and locator LED light will illuminate. If the Model 203-003

Interior Lighting Kit has been installed, it will also illuminate.

CAUTION

The lighting kit LEDs are very bright, and care should be taken to protect the eyes as necessary
if the stanchion body is removed.

3. Ensure that the mounted telephone is on an active line and all programming to the telephone is

complete in accordance with its instruction manual. Depress the red button to test that the telephone
dials to the proper phone number and the beacon activates. After the open line is disconnected, the
beacon will stop flashing. Refer to the connection diagram in Figure 5 and phone’s user manual to
troubleshoot any problems. For handset version phones, lifting the handset from the cradle should
activate the beacon.

4. After all testing has been successfully completed, attach the supplied gasket and cover to the

weatherproof boxes. Wrap the supplied closure plug threads with Teflon

®

tape, and use them to seal

any open access holes.

5. If the stanchion has the interior lighting kit installed, check the location of all wires before screwing

the enclosure shut. If wire shadows are cast in an unacceptable manner on the main stanchion, make
adjustments by lifting the bottom of the main stanchion body away from the wall approximately 8–10
inches. Adjust any wires as necessary, and replace the stanchion body parallel to the wall.

6. The screw attachment locations on the rear mounting panel will be in line with the countersunk holes

in the main stanchion body when the mounting plate, mounting surface, and stanchion main body are
parallel. Attach the two supplied 10-32 tamper-resistant screws into the screw hole locations located
on the bottom of the stanchion to secure the body.

Advertising