Stanchion Mounting

The LITE Series Stanchion mounting plate has four 5/16-inch diameter mounting holes for attaching the
stanchion to the wall.

1. Fasten the mounting plate to a wall or flat surface that can support at least 25 pounds, using 1/4-inch

bolts and fender washers (customer supplied) for attachment. Refer to Figure 4 for mounting hole
dimensions and suggested mounting height.

NOTE

It is the installer’s responsibility to mount the stanchion at a height in

accordance with the American Disabilities Act (ADA) and any other applicable codes.

2. Determine the method of routing the external power cable into the stanchion. The external power

cable can be routed to enter the stanchion through the bottom or the back of the mounting plate.
Refer to Figure 4.

3. The bottom of the mounting plate contains three locating holes for cable entry. Remove the bottom

weatherproof box before drilling. Drill out the center hole with enough clearance to allow 1/2 NPT
conduit entry into the weatherproof box for power cable entry.

4. If entering through the back of the mounting plate, drill a hole with enough clearance to allow 1/2

NPT conduit entry into the weatherproof box. Remove the 1/2-inch conduit hole plug from the rear
of the weatherproof box to locate the drilled hole location.

5. The left or right hole at the bottom of the mounting plate can be drilled to allow wire entry for the

telephone PBX line.