External power for –003ad models, Connecting a model 530 series strobe – GAI-Tronics 393-001AD, RED ALERT Auto-dial Telephones User Manual

Page 15

Advertising
background image

P

UB

.

42004-472B

A

UTO

-D

IAL

T

ELEPHONE

M

ANUAL

P

AGE

13 of 33

f:\standard ioms - current release\42004 instr. manuals\42004-472b.doc
01/15

External Power for –003AD Models

The Plug-in Power Supply is used for operations below −4º F (−20º C) and requires 120 V ac input to
provide a 5 V dc output to the unit. The Plug-in Power Supply is provided with a connectorized, 4-foot
power cable that plugs into P17 on the telephone PCBA. Remove the jumper from P17 pins 3 and 4 and
insert to the adjacent header J18 when using the plug-in power supply. See Figure 11 on page 16 for
jumper locations.

N

OTE

: The external power supply provided with these models does not provide telephone line power for

communications. It simply activates a heater circuit to allow operation to −40 ºC.

Connecting a Model 530 Series Strobe

Figure 10 below shows a typical connection detail of the GAI-Tronics 530-001/531A Strobe (sold
separately).

Figure 10. (Model 397-00xAD is shown as an example)

Connection to Optional GAI-Tronics 530-001/531A Strobe