Installation, Safety guidelines – GAI-Tronics 393-001AD, RED ALERT Auto-dial Telephones User Manual

Page 7

Advertising
background image

P

UB

.

42004-472B

A

UTO

-D

IAL

T

ELEPHONE

M

ANUAL

P

AGE

5 of 33

f:\standard ioms - current release\42004 instr. manuals\42004-472b.doc
01/15

Installation

ATTENTION

Installation should be performed by qualified personnel and only in

accordance with the National Electrical Code or applicable local codes.

Safety Guidelines

When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:

 Do not install telephone wiring during a lightning storm.
Electrostatic Discharge (ESD) Protection: Your telephone may have an earth ground terminal

provision. If so, ensure that it is connected to ground in accordance with all local safety regulations
and the National Electrical Code (NEC). Grounding has to be ensured for safe and stable
communications. Do not use long and coiled ground wires. Trim ground wires to the required
length. Use a star configuration whenever possible. Please note proper grounding does not eliminate
the need for lightning protection for the telephone or the telephone system.

Install a UL Listed lightning arrestor on any telephone installed where the telephone or telephone

cable is at risk of being exposed to lightning strikes. The lightning arrestor must be installed as close
to the telephone as possible to maximize the protection. It must not be installed within the enclosure
supplied with the telephone.

 Do not install telephone jacks in wet locations unless the jack is specifically designed for wet

locations.

 Do not touch uninsulated telephone wires or terminals unless the telephone line has been

disconnected at the network interface.

Advertising