GAI-Tronics 393-001AD, RED ALERT Auto-dial Telephones User Manual
Page 31
P
UB
.
42004-472B
A
UTO
-D
IAL
T
ELEPHONE
M
ANUAL
P
AGE
29 of 33
f:\standard ioms - current release\42004 instr. manuals\42004-472b.doc
01/15
Table 11. Programming Documentation Table
Function
Key Sequence
Default
Settings
User Settings
Auto-dial or Ring-Down Programming (see Table 3 on page 23)
CALL
Button Auto-dial Number 1
DD*1
*123456789*0#
CALL
Button Auto-dial Number 2
DD*2
None
CALL
Button Auto-dial Number 3
DD*3
None
Primary Dial Tone Delay
#10NN
3
seconds
Secondary Line Dial Tone Delay
#11NN
2
seconds
Ring-down Operation
*1
None
Password Protection Feature Programming (see Table 4 on page 24)
#14NNNN
2468
Disconnect Options Programming (see Table 6 on page 25)
Emergency Push-button Disconnect
#17L
1
(enabled)
Call Time-out Disconnect
#12NN
10
minutes
Dial Tone Disconnect
#19L
0
(disabled)
ADA Programming (see Table 7 on page 26)
DTMF Disconnect Option
#18L
1
(enabled)
Identification Code Entry
#13LNNN
None
Other Programming Features
Auto-Answer Alert Feature
(see Table 5 on page 24)
#16L
0
(disabled)
Extended Strobe Operation
(see Table 8 on page 26)
NN…*8
#26NNN
90125
#26050 (5 sec.)
Output 4 Control Setup
(see Table 9 on page 27)
#25NNN
0 0 0 (disabled)
Early Microphone Option
(see Table 10 on page 28)
#71L
0
(disabled)
Table Legend
D = DTMF digit 0–9, *, or #
N = Numeric digit 0–9 L = 0-Disable, 1-Enable