Parameter Function

REGISTERED +

Sets the output to pulse when the telephone is
registered with at least one SIP server. Can
be used as a “phone available” indicator. The
pulsing on /off periods are set by the
CADENCE field.

EMERGENCY +

Sets the output to pulse whenever there is an
outgoing call present that has been initiated by
an EMERGENCY button. The pulsing on
/off periods are set by the CADENCE field.

N

OTE

: The ON and OFF keywords must be used on their own. The

other keywords (indicated by a + symbol), can be combined and
entered in any order, separated by the plus (+) character.
For example, to set an output to pulse when an incoming call is
ringing, and be on steadily when the call is connected enter
RING+CONNECT.

TIMER

Sets the timer value for the PULSE command in seconds.
Default value is 3. The minimum is 0 and the maximum is 3600.

CADENCE

Sets the cadence for those keyword commands that require it. The
cadence is entered as two numbers separated by a colon (:) character,
representing the on and off times in tenths of a second. For example,
to set a cadence of 1 second on, half a second off, enter 10:5.