Troubleshooting

The following tables are provided to aid qualified service personnel in troubleshooting problems with the
ICS Page/Party

®

Replacement Amplifiers.

Table 1. Troubleshooting for All Models (Except as Noted)

Problem Potential

Cause

Station not
functional

• Verify incoming supply voltage at TB2 or TB3 on the Termination PCBA.
• Verify regulated 24 V dc at P1 of Termination PCBA. Caution! Supply

voltage present at P2.

Excessive hum or
buzz during
station operation.

Inspect the Page/Party

®

lines for proper line terminations, shorts, and grounds.

Crosstalk occurs
between
Page/Party

®

lines.

• Inspect the Page/Party

®

lines for proper line terminations, shorts, and

grounds.

• Inspect the Page/Party

®

party line connections for crossing of the cable pairs.

Feedback occurs
during page.

• Check location and orientation of speakers in the area.
• Refer to the “Speaker Mute” section for the applicable model.

Squeal in handset
receiver.
(Not applicable to
speaker amplifier
models.)

• Ensure proper termination on Page/Party

®

lines.

• Ensure system line balance is connected.

Speaker level is
too low/loud.

• Speaker volume potentiometer is not adjusted properly.
• Ensure the nominal page line level is correct.
• Replace the speaker or driver.

Cannot make a
page
(Not applicable to
speaker amplifier
models.)

• Check handset (or headset) connections
• Check proper cable terminations between Termination and Main PCBA.
• Check jumper settings or cable connections at P4.
• Replace handset.

Advertising