Connections, Power connection, Radio connection – GAI-Tronics ILD1000A Local Deskset User and Installation Manual User Manual

Page 15

Advertising
background image

ILD1000A Local Desk Set

Installation

11

02/12

Connections

Cable length limitations are imposed by power losses in the cable and stray noise pickup on the
microphone line. Cable length should be less than 1000 feet to maintain satisfactory performance.

To make the required line connections, a cable with tinned bare leads stripped to about 1/4 inch (6 mm)
is necessary. All interface connections are made inside the unit. To open the housing, remove the four
screws in the corners on the back housing and lift off the top cover.

Desk sets powered by a wall transformer or base station power supply can be connected in parallel on a
single cable. Refer to the radio manual and schematics to locate connection points. If they can not be
located, contact the manufacturer's technical support group. Multiple cable tie points are not provided.

Power Connection

Make the power connection to a 12 V dc source capable of supplying up to 0.5 A per desk set. This may
be obtained from a direct connection to the radio power supply.

N

OTE

: Do not obtain power for the desk set from the radio accessory connector. Damage to the radio

may result.

As an option, power can be supplied to the ILD1000A Desk Set from a listed Class 2 120 V ac wall
adapter. (The desk set is rated as Class III SELV powered equipment). The ac adapter is necessary if:
 more than one unit is connected to a single base station, or
 if the desk set is used more than 300 feet from the base station.
The desk set can operate on dc input voltages from 10.5 to 16 volts. Connect the power supply as
follows:

Positive (white striped) lead to Terminal Strip 1, terminal 1
Negative (black) lead to Terminal Strip 1, terminal 8

Radio Connection

All power and radio interface connections are made to the eight-position terminal strip on the main
circuit board. The desk set must be opened for access to this terminal strip.

1. Route the cable through the slot on the bottom rear corner of the desk set housing.

2. Loosen the eight slotted screws on the terminal strip and insert the cable wires into position

according to the terminal strip table below.

3. After connections to the radio cable and dc supply have been made, verify the positions to ensure

they are correct.

4. Apply power. Press the PTT pressbar on the handset to test the transmit function and the

MONITOR

button to test the receive function.

Advertising