GAI-Tronics MI05-101 Merge / Isolate Cabinet with External Option User Manual

Page 10

Advertising
background image

Pub. MI05-101iom.2

Model MI05-101 Merge/Isolate Cabinet

Page: 10 of 24

\\86h27g1-fs\iomdocs\opnotes -- released\mi05-00x merge-isolate cabs\mi05-101.dir\mi05-101iom2.doc
01/09

Enable/Disable the Call-In Feature

Jumpers are provided on the Termination PCBA to
enable or disable the Call-In feature for each zone.

 To enable the Call-In feature, jumper pins 2 and 3

on the Termination PCBA.

 To disable the Call-In feature, jumper pins 1 and 2

on the Termination PCBA.

Configuring Common Party Lines between Zones and Master Station

Jumpers are provided on the Termination PCBA to make party lines 2 through 5 common across zones
and the master station(s). When a party line is made common between zones and the master station, any
station can pick up a handset and join the conversation.

 To make a party line common, jumper pins 1 and 2 on the jumper assigned to the zone or master

station party line.

 To isolate the party line, jumper pins 2 and 3 on the jumper assigned to the zone or master station

party line.

The following table lists the jumpers for each zone.

Zone

Party Line 2

Party Line 3

Party Line 4

Party Line 5

1

JB11 and JB12

JB13 and JB14

JB15 and JB16

JB17 and JB18

2

JB19 and JB20

JB21 and JB22

JB23 and JB24

JB25 and JB26

3

JB27 and JB28

JB29 and JB30

JB31 and JB32

JB33 and JB34

4

JB35 and JB36

JB37 and JB38

JB39 and JB40

JB41 and JB42

5

JB43 and JB44

JB45 and JB46

JB47 and JB48

JB49 and JB50

Master

N/A

N/A

JB51 and JB52

JB53 and JB54

Zone

Call-In Feature Jumpers

1

JB1 and JB2

2

JB3 and JB4

3

JB5 and JB6

4

JB7 and JB8

5

JB9 and JB10

Advertising