Machine interface pinout – Hypertherm Duramax Hyamp Robotic Torch User Manual

Page 43

Advertising
background image

Duramax/Duramax Hyamp Robotic Torches Service Manual 807460

43

2 – Torch Setup

Machine interface pinout

Figure 18 – Connector sockets

Refer to

Table 1 when connecting the power supply to a torch height controller or CNC controller with a machine

interface cable.

Table 1 – Machine interface cable signals

Signal

Type

Notes

Connector
sockets

External cable wires

Start (start plasma)

Input

Normally open.

18 VDC open circuit voltage at
START terminals. Requires dry
contact closure to activate.

3, 4

Green, black

Transfer (start machine
motion)

Output

Normally open. Dry contact closure
when the arc transfers.

120 VAC/1 A maximum at the
machine interface relay.

12, 14

Red, black

Ground

Ground

13

Voltage divider

Output

Divided arc signal of 20:1, 21.1:1,
30:1, 40:1, 50:1 (provides a
maximum of 16 V).

5 (-), 6 (+)

Black (-), white (+)

3

4

5

6

12

13

14

Advertising