Power Requirements:
Refer to HT4001 power supply specifications below:

Gas Requirements:
Plasma Gas Types .............................................. Oxygen (O

2

), Nitrogen (N

2

)

Gas Quality

Oxygen ......................................................... 99.5%
Nitrogen ........................................................ 99.995%

Oxygen Gas Inlet Pressure ................................. 120 psi (8.3 bar)
Nitrogen Gas Inlet Pressure ................................ 150 psi (10.3 bar)
Air Gas Inlet Pressure (for Water Muffler) ........... 120 psi (8.3 bar)

Water Requirements:
Water Flow .......................................................... 0.5 gpm (1.9 l/m) to water chiller

2.5 gpm (9.5 l/m) to RHF console

Water Inlet Pressure ........................................... 35 psi (2.4 bar) to water chiller

150psi (10.3 bar) to RHF console

1

HT4001 Power Supply

Maximum OCV (U

0

) ............................................. 325 VDC

Maximum Output Current (I

2

) .............................. 400 A

Output Voltage (U

2

) ............................................. 80-200 VDC

Duty Cycle Rating (X) .......................................... 100% @ 40

°C at 400 A and 200 V

Ambient Temperatures/Duty Cycle ..................... Power supplies will operate between +14

° and

104

°F (-10° and +40°C).

Power supplies operated in an ambient
temperature above 86

°F (30°C) may show some

decrease in duty cycle.

Cooling ................................................................ Forced Air (Class F)

Dimensions and Weight
Width ................................................................... 34" (863 mm)
Maximum Height ................................................. 51" (1295 mm); 63" (1600 mm) on CE and

200/220V units

Maximum Depth .................................................. 48-11/16" (1236 mm)
Weight ................................................................. 1800 lbs (817 kg); 1850 lbs (840 kg) on CE units

Figure 2-1 HT4001 Power Supply Dimensions

48-11/16"

32"

39-1/2"

34"

48"

1-97