IDK MSD-54 Series User Manual
Page 159

159
DELIMITER
*1 *2
Set the delimiter to be sent at the end of the received
data.
“NONE”: delimiter is not checked and all received data
within the set timeout will be valid.
Value other than “NONE”: delimiter is checked and
data received before delimiter will be valid.
NONE [Default]
00 to FF (Hex)
RCV CHECK
*1
*3
Set whether reply command that may be returned is
checked or not.
CHECK Default
NOT CHECK
TIME OUT
*1 *4 *5
Set the timeout time for reply command to a sent
command.
0 ms. to 99 seconds and 999
ms.
[Default]: 0 ms.
RETRY
*1 *4 *5
Set the number of retries to resend the same
command again if no valid response is replied.
0 to 99
[Default]: 0
INTERVAL
*1 *4 *5
Set the retry interval to resend the command.
0 ms. to 99 seconds and 999
ms.
[Default]: 0 ms.
ERROR
*1 *4 *5
Set whether the next command is to be executed or
not if no valid response is replied, even after
completing retry for the set number of retries.
STOP: [Default]
EXEC: Continue
Tally output
control
*8
Set the control of pins 22 to 24 and 47 to 49 of Tally
output.
“TGL” (toggle operation): contact points are switched
from OFF to ON or vice versa.
-: Not control [Default]
OFF
ON
TGL
PULSE
*8
Set the waiting time before the status is put back after
controlling contact points with Tally output.
NONE: Eternal [Default]
100 ms. to 9990 ms. (by 10
ms.)
HDMI CEC
control
*9
Set the CEC control for the display devices connected
to HDMI connectors of OUT1 to OUT4.
-: Not control [Default]
POWER OFF
POWER ON
Process for CEC
error
*9
Set whether the next command is executed or not if no
response is replied from the display device that is
controlled with CEC.
STOP [Default]
EXEC: Continue
MEMO
Register a note up to 14 characters.
The registered note is displayed when the control
command is executed.
20 to 7D of “9 ASCII codes”
except for 2C (,)
[Default]: All spaces
*
1
If “Port” is set to ”Tally” or “CEC”, you do not need to set this item.
*
2
If “RECV DISPLAY” is set to “OFF”, you do not need to set this item.
*
3
If “RECV DISPLAY” is set to “ASCII” or “HEX”, you do not need to set this item.
*
4
If only “LOOP BACK” of communication ports is set to “ON”, you do not need to set this item.
*
5
If all “RCV CHECK” is set to “NOT CHECK”, you do not need to set this item.
*
6
If either “RS-1” or “RS-2” is set to “ON”, set “8.10.2 Operation mode” to “TRANSMITTER”.
*
7
If any LAN connections for “LAN1” to “LAN8” are set to “ON”, set “8.11.4 Operation mode” to
“TRANSMITTER”.
*
8
If “PORT” is set to “COM” or “CEC”, you do not need to set this item. For Tally output pins that are set to
“Not control”, set ”8.15.1 Assigning functions” to “Control command output”.
*
9
If “PORT” is set to ”COM” or “Tally”, you do not need to set this item.