8 troubleshooting, 1 blank screen, 1 blank – IHSE USA 238 Series Media Converter User Manual

Page 57: Screen, Troubleshooting

Advertising
background image

Troubleshooting

2013-08-13

57

8 Troubleshooting

Pos: 55 /806-IHSE/Hilfe im Problemfall/Bildausfall/238-5v-xx @ 5\mod_1291135198546_6.doc @ 45710 @ 2 @ 1

8.1

Blank Screen

Diagnosis

Possible Reason

Measure

Status LED
blue

No video signal detected  Check

connections.

Check input selection in the

OSD (source type).

Load DDC information of the

connected monitor (see Chapter
6.2, Page 39).
Reboot CPU if necessary.

Status LED
green

No monitor detected

Check connection, length and

quality of the DVI-D cable to
monitor, tighten cable
thumbscrews.

No monitor detected

Check connection, length and

quality of the DVI-D cable to
monitor, tighten cable
thumbscrews.

Status LED
dark red

Resolution on device
side not supported

Fill in the video mode

questionnaire (

Download

), so

that a customer specific video
mode can be made.

Status-LED
violet

Resolution on device
side not supported

Fill in the video mode

questionnaire (

Download

), so

that a customer specific video
mode can be made.


Pos: 56 /806-IHSE/Hilfe im Problemfall/Bildstörung/238-5v-xx @ 5\mod_1291135234578_6.doc @ 45729 @ @ 1

Advertising