2 picture, 3 general – IHSE USA 238 Series Media Converter User Manual

Page 58

Advertising
background image

K238 Media- / DVI-Converter

58

2013-08-13

8.2

Picture

Diagnosis

Possible Reason

Measure

Connection between
disturbed

Check connection, length and

quality of the DVI-D cable to
monitor, tighten cable
thumbscrews.

Incorrect picture
display

Transmission
parameters not suitable
or not optimally set for
conditions.

Run 'Auto Configuration'

(see Chapter 5.3.2, Page 27).

If necessary, set parameters for

picture settings manually (e.g.
phase and clock) (see
Chapter 5.3.2, Page 27).

Parts of the
picture are
missing

Wrong setting of picture
size

Optimize picture settings (see

Chapter 6.1, Page 37).

Horizontal
picture jitter

Wrong settings of phase
and clock

Readjust phase and clock

manually (see Chapter 5.3.2,
Page 27).

Characters are
smeared

Wrong setting of phase

Readjust phase manually (see

Chapter 5.3.2, Page 27).

Fine vertical
lines are
missing

Wrong setting of clock

Readjust clock manually (see

Chapter 5.3.2, Page 27).


Pos: 57 /806-IHSE/Hilfe im Problemfall/Allgemeine Störung/238-5v-xx @ 5\mod_1291135298421_6.doc @ 45749 @ @ 1

8.3

General

Diagnosis

Possible Reason

Measure

Infrared remote
control is non-
functional

Wrong device selected

Press the button <DEV ALL> on

the infrared remote control to get
a device-independent access to
the functions.