Firing parameters

IPS InLine

Veneers

T

°C/°F

B

°C/°F

S

min

t

°C/°F/min

H

min

V

1

°C/°F

V

2

°C/°F

Wash Firing

830/1526

403/757

4

60/108

1

450/842

829/1524

Cervical firing

940/1724

403/757

8

60/108

1

450/842

939/1722

Dentin / Impulse firing

940/1724

403/757

8

60/108

1

450/842

939/1722

Incisal firing

930/1706

403/757

8

60/108

1

450/842

929/1704

Glaze firing

860/1580

403/757

8

60/108

1

450/842

859/1578

T = Firing temperature °C/°F

B = Stand-by temperature °C/°F

S = Closing time in minutes

t

= Heating rate °C/°F/min

H = Holding time

V

1

= Vacuum on temperature °C/°F

V

2

= Vacuum off temperature °C/°F

these firing parameters are guidance values. they are valid for the Programat furnaces from Ivoclar vivadent.
Deviations (approx. +/- 10 °C/18 °F) may occur:
– Depending on the furnace generation.
– If ceramic furnaces from other manufacturers are used.
– In case of regional differences in the power supply or if several electrical devices are operatated on the same circuit.