14 en, 3 welding parameters – Kemppi FastMig X 350 User Manual

Page 16

Advertising
background image

FastMig X 350, X 450

14

EN

4.2.4 Creating the first MMA/CC/CV memory channel

If you are starting with a new FastMig X power source that contains no MMA/CC/CV memory

channels, follow these steps to create the first MMA/CC/CV memory channel.

1.

Press MENU button to display the main menu.

2.

With up and down arrows, browse to MMA/CC/CV Mode (7/7) and press SELECT.

• MMA/CC/CV Mode view appears

3.

With the control knob, select ON and press SELECT.

• An empty MMA/CC/CV memory channel appears.

4.

When an empty MMA/CC/CV memory channel appears, press NEW soft key.

5.

With Create New selected, press SELECT soft key.

6.

Select MMA, CC or CV and other parameters.

7.

When you have made all settings, press SAVE soft key to store the settings in the active

memory channel.

4.2.5 Creating and modifying memory channels

1.

Press MENU button to display the main menu.

2.

With Edit Channel selected, press SELECT.

3.

Select the channel number to be changed and press SELECT.

• Use up and down arrow buttons to browse the displayed channel numbers.

• Use Channel Info (F1) button to see the show the settings of the displayed channel.

• To create a new channel, select a channel that is marked (Empty).

4.

Browse the menu to select the desired options and parameters.

• Use up and down arrow buttons to move around in the menus.

• Approve selections by pressing the SELECT soft key.

• See the welding parameters and functions section of this manual.

5.

When you have made all settings, press SAVE soft key to store the settings in the selected

memory channel number.

When you have created a memory channel, the system is ready to weld. You select the desired

memory channel number on wire feeder's control panel, set the welding power and arc length

and start welding.

4.3 Welding parameters

MIG

WFSpeed

0.7…25 m/min

Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min

WFS-Max

Sets the limit for maximum WFSpeed

WFS-Min

Sets the limit for minimum WFSpeed

Voltage

8…50 V

Step: 0.1

Controls the length of the arc

VoltageMax

Sets the limit for maximum voltage value

VoltageMin

Sets the limit for minimum voltage value

Dynamics

-9…+9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

Advertising
This manual is related to the following products: