Kemppi FastMig X 350 User Manual

Page 17

Advertising
background image

15

© Kemppi Oy / 1520

EN

1-MIG

WFSpeed

0.7…25 m/min *

Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min

WFS-Max

Sets the limit for maximum WFSpeed

WFS-Min

Sets the limit for minimum WFSpeed

FineTuning

-9.0 … +9.0

Factory setting is 0.0
( = curve point)

Adjusts the arc voltage of the curve (arc length) within
certain limits

FineTuningMax

-9.0 … +9.0

Step: 0.5

Sets the limit for maximum arc length

FineTuningMin

-9.0 … +9.0

Step: 0.5

Sets the limit for minimum arc length

Dynamics

-9 … +9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

PULSE MIG

WFSpeed

0.7…25 m/min *

Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed
< 5 m/min, and by 0.1, when WFSpeed > 5 m/min

WFS-Max

Sets the limit for maximum WFSpeed

WFS-Min

Sets the limit for minimum WFSpeed

FineTuning

-9.0 … +9.0

Factory setting is 0.0
( = curve point)

Adjusts the base current of the curve (arc length) in
certain limits

FineTuningMax

-9.0 … +9.0

Step: 0.5

Sets the limit for maximum arc length

FineTuningMin

-9.0 … +9.0

Step: 0.5

Sets the limit for minimum arc length

Dynamics

-9…+9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

Pulse Current

-10…+15%

Factory setting is
0 %

Reduces (–) or raises (+) the pulse current of the curve

DOUBLE PULSE MIG

WFSpeed

0.7…25 m/min *

Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min

WFS-Max

Sets the limit for maximum WFSpeed

WFS-Min

Sets the limit for minimum WFSpeed

FineTuning

-9.0 … +9.0

Factory setting is 0.0
( = curve point)

Adjusts the base current of the curve (arc length) in
certain limits

FineTuningMax

-9.0 … +9.0

Step: 0.5

Sets the limit for maximum arc length

FineTuningMin

-9.0 … +9.0

Step: 0.5

Sets the limit for minimum arc length

Dynamics

-9…+9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

Pulse Current

-10…+15%

Factory setting
is 0%

Reduces (-) or raises (+) the pulse current of the curve

DPulseAmp

0.1…3.0 m/min

Factory setting is
CURVE

Adjusts the amplitude of the WFSpeed by steps of 0.1.
Value comes from welding program.

DPulseFreq

0.4…8.0 Hz

Factory setting is
CURVE

Adjusts the frequency of the double pulse by steps of 0.1.
Value comes from welding program.

Advertising