Kemppi FastMig X 350 User Manual
Page 17

15
© Kemppi Oy / 1520
EN
1-MIG
WFSpeed
0.7…25 m/min *
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min
WFS-Max
Sets the limit for maximum WFSpeed
WFS-Min
Sets the limit for minimum WFSpeed
FineTuning
-9.0 … +9.0
Factory setting is 0.0
( = curve point)
Adjusts the arc voltage of the curve (arc length) within
certain limits
FineTuningMax
-9.0 … +9.0
Step: 0.5
Sets the limit for maximum arc length
FineTuningMin
-9.0 … +9.0
Step: 0.5
Sets the limit for minimum arc length
Dynamics
-9 … +9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
PULSE MIG
WFSpeed
0.7…25 m/min *
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed
< 5 m/min, and by 0.1, when WFSpeed > 5 m/min
WFS-Max
Sets the limit for maximum WFSpeed
WFS-Min
Sets the limit for minimum WFSpeed
FineTuning
-9.0 … +9.0
Factory setting is 0.0
( = curve point)
Adjusts the base current of the curve (arc length) in
certain limits
FineTuningMax
-9.0 … +9.0
Step: 0.5
Sets the limit for maximum arc length
FineTuningMin
-9.0 … +9.0
Step: 0.5
Sets the limit for minimum arc length
Dynamics
-9…+9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10…+15%
Factory setting is
0 %
Reduces (–) or raises (+) the pulse current of the curve
DOUBLE PULSE MIG
WFSpeed
0.7…25 m/min *
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min
WFS-Max
Sets the limit for maximum WFSpeed
WFS-Min
Sets the limit for minimum WFSpeed
FineTuning
-9.0 … +9.0
Factory setting is 0.0
( = curve point)
Adjusts the base current of the curve (arc length) in
certain limits
FineTuningMax
-9.0 … +9.0
Step: 0.5
Sets the limit for maximum arc length
FineTuningMin
-9.0 … +9.0
Step: 0.5
Sets the limit for minimum arc length
Dynamics
-9…+9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10…+15%
Factory setting
is 0%
Reduces (-) or raises (+) the pulse current of the curve
DPulseAmp
0.1…3.0 m/min
Factory setting is
CURVE
Adjusts the amplitude of the WFSpeed by steps of 0.1.
Value comes from welding program.
DPulseFreq
0.4…8.0 Hz
Factory setting is
CURVE
Adjusts the frequency of the double pulse by steps of 0.1.