FastMig X 350, X 450

20

EN

Pre Gas Time

0.0…9.9 s, CURVE.

Step: 0.1
Factory setting is CURVE

CURVE: Pre Gas time is read from the
Welding program.
0.0 – 9.9s: User Pre Gas time setting.

Post Gas Time

0.0…9.9 s, CURVE.

Step: 0.1
Factory setting is CURVE

CURVE: Post Gas time is read from the
Welding program.
0.0 – 9.9s: User Post Gas time setting.

Control *

USER, PANEL,
REMOTE, GUN.

Factory settings is USER

This setting affects the XF 37 (or XF 38)
control panel remote control unit selection.
USER: User can select the remote control
device at XF 37 panel
PANEL: Selection is locked to PANEL, and
user can not select the remote device at
XF 37 panel.
REMOTE: Selection is locked to HAND
REMOTE device.
GUN: Selection is locked to GUN REMOTE
device.

RemoteAutoRecog

ON, OFF.

Factory setting is ON

Automatic remote control unit recognition.
ON: Remote control units are recognized.
Wire feeder panel XF 37 (or XF 38) jumps
to PANEL selection, if the selected remote
control unit disappears.
OFF: Remote control units are not
recognized. Remote control unit selection
remains unchanged if the selected remote
control unit disappears.

MIG CurrentDisp

ON, OFF

Factory setting is OFF

ON: Displays amperage (A) preset values
OFF: Displays wire feed speed (m/min).

WFMotorWarnLev

1.5…5.0 A

Factory setting is 3.5A

The alarm level of wire feed motor current.
Check/service wire feed mechanism,
adjustment and gun components.

WF End Step

ON, OFF

Factory setting is OFF

ON: The filler wire steps forward at the end
of the welding cycle.
OFF: Filler wire remains static at the end of
the welding cycle.

AutoWireInch

ON, OFF

Factory setting is ON

Automatic SuperSnake Wire Inch feature.
When ON, the Wire Inch button drives the
filler wire automatically up to SuperSnake.

Gas Guard

ON, OFF

Factory setting is OFF

Turns the gas guard on and off, provided
that one is installed.

ArcVoltage

ON, OFF

Factory setting is OFF

Measured and calculated arc voltage.
This must be calibrated using voltage
measurement cable.
If ON, welding panel and subfeeder/R30
shows arc voltage value in voltage display.

SubFeederLength

10...25 m

Factory setting is 10 m

Sub feeder length selection for arc voltage
calculation.

* When connecting a remote control device to the power source in MMA/CC/CV welding,

you don't need to make adjustments to this setting. Remote control device is automatically

recognised, when USER option is selected (default) and RemoteAutoRecog=ON.