Dinscbg.vi – Measurement Computing UL for NI LabVIEW User Manual

Page 76

Advertising
background image

Universal Library Virtual Instruments (VIs)

Digital I/O VIs

DInScBg.VI

Performs multiple reads of digital input port of a high speed digital port on a board with a pacer clock such as
the CIO-PDMA16.

When this VI is used, control will return immediately to the next point in your program and the transfer from
the digital input port to the array in the Context will continue in the background. Use GetStatus.VI to check on
the status of the background operation. Use StopBg.VI to terminate the background process before it has
completed. StopBg.VI should be used after any background operation to clear variables and flags.

Summary:

Inputs:

BoardNum

[U32] - The board number assigned when installed with InstaCal. Can

be 0 to 100.

PortNum

[I32] - Specifies which digital I/O port to read.

Count

[I32] - Number of times to read digital input.

Rate

[I32] - Number of times per second (Hz) to read.

Continuous

[TF] - Continuous or single

ExtClock

[TF] - External or internal clock

WordXfer

[TF] - Word or byte transfer

Outputs:

Context

[cluster] - Output data structure.

Rate

[I32]- Actual rate returned here

ErrCode

[I32] - Error code. See ErrMsg.VI

Arguments:

BoardNum

The board number associated with a board when it was installed with InstaCal.

PortNum

If the port type is not

AUXPORT

, the specified port must be configured for input.

For many boards, AUXPORT is not configurable. However, some later boards do

require that the AUXPORT be configured using DCfgPort.VI or DCfgBit.VI.
Please see board details for more information.

Count

The number of times to read digital input.

Rate

Number of times per second (Hz) to read the port. The actual sampling rate in

some cases will vary a small amount from the requested rate. The actual rate will
be returned to the

Rate

output argument.

Continuous

This option (if True) puts the VI in an endless loop. After it transfers the required

number of bytes it resets to the start of the input array and begins again. The only
way to stop this operation is with StopBg.VI (a single execution is False).

ExtClock

If this option is used (True) then transfers will be controlled by the signal on the

trigger input line rather than by the internal pacer clock. Each transfer will be
triggered on the appropriate edge of the trigger input signal (see board-specific
info). When this option is used, the

Rate

argument is ignored. The transfer rate is

dependent on the trigger signal. The default is

TIMED

(False).

WordXfer

Normally (default is False) this VI reads a single (byte) port (

BYTEXFER

). If

WORDXFER

is specified, it will read two adjacent ports on each read and store the

value of both ports together as the low and high byte of a single array element in
the input array.

Rate

(output)

Actual sampling rate in samples per second.

76