Status for LS3400 (SYN)

Display

Priority*

Description

ERR

1 Error (M200

–M205), com error

Mntc

2 Maintenance (M234)

FWA

3 Circulation (M235)

ON

4 In operation

* When two status reports occur at once, that with lower priority is shown.

Info on LS3400 (SYN)

Display

Priority*

Description

Com err

1 Communication error

Cap err M

2 Capability error: CenterPur cannot fulfil the function required.

Causes: Firmware not updated, device technology outdated

Cap err D

3 Capability error: LS cannot fulfil the function required.

Causes: Firmware not updated, device technology outdated

Safety press. err

7 Safety pressure error (M200)

Inlet press. err

9 Inlet pressure error (M201)

Gas press. err

8 Gas pressure error (M202)

Motor prot. err

6 Motor protection error (M203)

Synthesis err

5 Synthesis error (M204)

Product err

4 Product error (M205)

Mntc Syn

10 Maintenance (M234)

SynPur ready

11 PER ready for operation

* When two status reports occur at once, that with lower priority is shown.

Parameters for HPS 3200 (HIG)

Name

Function

Notes

Dtype:

Device type

HPS3200 (M261, M262, M263, D250)

DNum:

Device number

(D250,D251)

Stat:

Summary of status

See table below

Info:

Additional status information

See table below

Status for HPS 3200 (HIG)

Display

Priority*

Description

ERR

1 Error (M200

–M204), com error

ON

2 Pump running (M232)

Stdby

3 No malfunction, pump off

* When two status reports occur at once, that with lower priority is shown.