Ò³ãæ 34, 7 external alarm installation, Data in – Onwa Marine Electronics KAP-866 User Manual

Page 34

Advertising
background image

Data In

For GPS navigation or heading information, Connect the data output and data

output and data return wires of external device to the IN+ and IN- of KAP-866

GPS connector. Onwa KGN100 or KGN200 is supplied as an option to convert

the analog signa l (sychro or stepper) of gyrocompass onboard to NMEA0183

data as heading source to KAP-866.

Digital heading source

GPS device

3.7 External Alarm Installation

An external buzzer may be connected to the ALA + and ALA - of KAP-866

Alarm connector

The ALA- output will be 10 volts when the alarm is not sounding (with alarm

connected), and approximately 0 volts when active. We recommends a 12-volt

piezo buzzer with maximum current draw not exceeding 250 milliamps be

connected to this output.

If a larger type siren or alarm unit, which draws in excess of 250 milliamps is

used, this must be connected via a relay. The KAP-866 external alarm circuit

is used to energise the relay coil and power to the siren or alarm unit is conn-

ected via the relay contacts.

.

29

AUTOPILOT

COMPASS

REMOTE

RUDDER

MOTOR

ALA/RUDM

NMEA I/O

POWER IN