Ò³ãæ 39, 2 troubleshooting, Troubleshooting – Onwa Marine Electronics KAP-866 User Manual

Page 39

Advertising
background image

5.2 Troubleshooting

This section provides basic troubleshooting procedures which the user may

follow to restore normal operation.

Troubleshooting

Symptom

Cause

Remedy

Cannot turn on

the power

Power cable on the
display unit

Power supply failure

Blown fuse

Firmly connect the power
cable

Check the power supply.

Heading indication
changes randomly
when ship is at
anchor or does
not change when
ship moves.

Sensor trouble or
Cable contact is bad.

Run the diagnostic test
to determine cause.

Replace fuse with correct
rating. Have a qualified
technician to check if
fuse blown again after
replacement.

Rudder not
functioning

No rudder angle
indication

RFU problem or RFU

cable contact is bad

1. Check voltage supply to

KAP-866

2. Check the steering system

1. Check RFU

2. Check RFU cable

3. Check RFU and rudder
connection

Low voltage output
from KAP-866 or
steering system problem

If large heading error occurs or heading indication is frequently interrupted,

contact your dealer for advice.

34

Advertising