Orion System MHGRV-X User Manual

Page 2

Advertising
background image

TABLE OF CONTENTS

MHGRV-X Field Technical Guide

2

WattMaster Controls Inc.
8500 NW River Park Drive · Parkville, MO 64152
Toll Free Phone: 866-918-1100
PH: (816) 505-1100 · FAX: (816) 505-1101
E-mail: [email protected]
Visit our web site at www.orioncontrols.com

www.aaon.com

WattMaster Form: AA-MHGRVX-FIELD-TGD-01H
Copyright April 2015 WattMaster Controls, Inc.
AAON

®

Manual Part No.: V16950

AAON

®

is a registered trademark of AAON, Inc., Tulsa, OK.

Neither WattMaster Controls, Inc. nor AAON

®

assumes any

responsibility for errors or omissions in this document.
This document is subject to change without notice.

CONTROLLER OVERVIEW ............................................................................................................... 3

Features ................................................................................................................................................................... 3

INSTALLATION & WIRING ............................................................................................................... 4

Important Wiring Considerations .............................................................................................................................. 4
MHGRV-X Controller to AAON Unit Controller Wiring.............................................................................................. 5
MHGRV-X Stand Alone Wiring ................................................................................................................................. 6

INPUTS AND OUTPUTS .................................................................................................................. 7

OPERATION OVERVIEW .................................................................................................................. 8

Initialization .............................................................................................................................................................. 8

Modulating Hot Gas Valves ...................................................................................................................................... 8
Modes of Operation ................................................................................................................................................. 8
Additional Features .................................................................................................................................................. 8

LCD DISPLAY SCREENS .................................................................................................................. 9

TROUBLESHOOTING ..................................................................................................................... 13

Using LEDs to Verify Operation ............................................................................................................................. 13
Temperature Sensor Testing ........................................................................................................................................ 14

APPENDIX A - Supply Air Temperature Sensor Guide ................................................................. 17

Supply Air Temperature Sensor Installation ........................................................................................................... 17
Supply Air Temperature Sensor Wiring Chart and Jumper Settings ...................................................................... 18

APPENDIX B .................................................................................................................................. 19

MHGRV-X Replacement of MHGRV II ................................................................................................................... 19

APPENDIX C .................................................................................................................................. 20

Reheat Expansion Module ..................................................................................................................................... 20

PART NUMBER CROSS REFERENCE TABLE

PART DESCRIPTION

ORION

AAON

TULSA

MHGRV-X Controller

OE377-26-00059

V12100

Reheat Expansion Module

OE377-01-00059

V42450

MODGAS-X Controller

OE377-26-00058

V12090

Supply Air Temperature Sensor

OE231

P87140

EBC E-BUS Cables - Varying Lengths

EBC-XXX-F

N/A