Installation inside buildings

Ensure there is adequate heat
dissipation when placing the
outdoor component in cellars,
attics, adjoining rooms or halls
(Fig 5)

.

Install an additional fan with
a rated flow comparative to
that of the outdoor component
being installed in the room.
This is used in conjunction with
ventilation ducts to compensate
any pressure losses (Fig 5).

Ensure a continuous and
unobstructed air flow from
outside, preferably using
sufficiently large air intakes placed
opposite each other (Fig 5).

Comply with any regulations
and conditions affecting
the statics of the building.
If necessary, fit acoustic
installation.

Minimum clearances

Warm air

Fresh

cold air

Light

well

Outdoor unit

Warm air

Light

well

Additional

fan

5 Installation inside buildings

Air intake

Air outlet

All values in mm

Minimum clearances

The adjacent illustration specifies
the minimum clearances required
to assure trouble-free operation of
the equipment.

These protection zones serve
to ensure unobstructed air flow
through the inlet and outlet
and provide sufficient space for
effecting maintenance and repairs
whilst also protecting the unit
against damage.

Air intake

Air outlet

E

D

C

A

B

RM

226 AT

RM

235 AT

RM

252 AT

RM

268 AT

RM

326 AT

RM

335 AT

RM

426 AT

RM

435 AT

A 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm

B 1300 mm 1300 mm 1500 mm 1500 mm 1500 mm 1500 mm 1500 mm 1500 mm

C 500 mm 500 mm 600 mm 600 mm 600 mm 600 mm 600 mm 600 mm

D 150 mm 150 mm 150 mm 150 mm 150 mm 150 mm 150 mm 150 mm

E

500 mm 500 mm 500 mm 500 mm 500 mm 500 mm 500 mm 500 mm