Remko rm – REMKO RM Series User Manual

Page 22

Advertising
background image

Connecting the indoor unit

Make the connection as follows:

1. Open the air inlet guard.

2. Unfasten the cover on the right

side and at the bottom right
rear (Fig 12).

3. Connect the unit to the

control cable from the outdoor
component.
See electrical connection
diagram

4. Re-assemble the unit.

Connecting the outdoor
component

Proceed as follows to connect the
cable:

1. Remove the equipment cover

by the connection.

2. Select the cable cross-section

according to the relevant
standards.

3. Feed both cables through the

edge protection rings on the
fixed connection panel.

4. Terminate the cables as shown

on the electrical connection
diagram.

5. Support the cable in the strain

relief and re-assemble the unit.
(Fig 13)

.

Check all plugged and clamped
terminals to verify they are
seated correctly and making a
permanent contact. Re-tighten
as required.

CAUTION

Terminal block

control cables

Cover

Control cable from

outdoor unit

Strain relief

Terminal block

Voltage supply

from outdoor component

Control cable from

outdoor unit

12

Connecting the indoor unit

13

Connecting the outdoor unit

Mark the electrical control cable
and associated refrigerant pipes
for each indoor unit with the
same letter (A to D).
Only connect up those cables/
pipes with the same letter.
The incorrect allocation of
control cables and refrigerant
pipes can have fatal
consequences, e.g. compressor
damage!

REMKO RM

22

13 Cable connections

Control cable Indoor unit C

Control cable

Indoor unit B

Control cable

Indoor unit D

Strain

relief

Control cable

Indoor unit B