Remko system monitor, For remko supertec inverter – REMKO SuperTec-Monitor User Manual

Page 14

Advertising
background image

Setting on SW2

System component

Measuring range and description

Unit

Heat exchanger temperature

sensor on the outdoor unit

(two-phase mixture) TH6

-39 – 88

-39 – +88

If the temperature sensor

measures values below 0°C,

the display switches between

the sign and the value.

°C

ON

1 2 3 4 5 6

Hot gas overheating tempera-

ture SHd

0 – 255

Cooling: TH4 - TH6

Heating: TH4 - TH5

0 – 255

If the temperature difference is

over 99 K, the display

switches between the 100s

digit and the 10s and 1s

digits.

K

ON

1 2 3 4 5 6

Cooling fin temperature sensor

TH8

-40 – 200

-40 – +200

If the temperature sensor

measures values below 0°C,

the display switches between

the sign and the value.

If the temperature is over

99°C, the display switches

between the 100s digit and the

10s and 1s digits.

°C

ON

1 2 3 4 5 6

Outdoor temperature TH7

-39 – 88

-39 – +88

If the temperature sensor

measures values below 0°C,

the display switches between

the sign and the value.

°C

ON

1 2 3 4 5 6

REMKO SYSTEM MONITOR

FOR REMKO SUPERTEC INVERTER

14