Changing the cartridge – Teac TN-300 User Manual
Page 14
14
Changing the cartridge
To change the cartridge, first remove the headshell from
the tone arm.
o
We recommend that you keep the cartridge needle
protective cap on while changing the cartridge.
Headshell
Cartridge
Shell leads
Screws
Nuts
1
Disconnect the shell lead terminals
from the cartridge.
2
Loosen the screws and remove the
cartridge.
3
Attach the new cartridge and tighten
the screws.
See the illustration below for the position of the
screws when attached.
2.0 ± 0.5 mm
4
Connect the shell lead terminals to the
cartridge.
o
The signals and colors of the shell leads are
shown below.
Signal
Color
Left channel +
White
Left channel −
Blue
Right channel +
Red
Right channel −
Green
5
Balance the tone arm and adjust the
stylus pressure.
Follow the procedures in “Balancing the tone arm
and adjusting the stylus pressure” on page 8.