Diagnostics, Loop mode, Bert function – Verilink PRISM 41TDM (34-00275.4) Product Manual User Manual

Page 33: Bert, Loop mode bert function

Advertising
background image

Diagnostics 25

Diagnostics

The Diagnostics screen allows testing functions to be performed on the network or
the DTE port. The unit recognizes inband loopback requests as well as local testing
and remote network management loopback test commands. The PRISM 41TDM
has an internal 511 pattern generator and comparator. The unit can transmit the
pattern toward the DDS line/network or toward the data port/DTE interfaces. Bit
Error Rate testing is available on Port B only when the unit is set to TDM mode.
shows the Diagnostics menu structure.

Loop Mode

Allows choosing how data is looped back. The options are Bidirectional and
Unidirectional.

BERT Function

The following menus offer selections for starting a BERT (Bit Error Rate Test)
along with test results.

BERT

This selection allows setting the BERT to Off, Net, DTE A - Net, DTE A - DTE,
DTE B - Net, or DTE B - DTE.

Off - Shuts down any BERT currently running.

Net - Initiates a full bandwidth BERT towards the DDS network. Because the
BERT takes up the entire DDS bandwidth, the FDL function (if active) is
interrupted.

DTE A - Net - In DDS-I or DDS-II mode, there is no discernible difference
between this selection and Net. However, in TXP-I or TXP-II mode, this menu
selection initiates a BERT that does not interfere with the FDL (or other DTE port,
if active).

DTE A - DTE - Initiates a BERT towards the DTE port A. DTE port B (if in TDM
mode) is not affected.

DTE B - Net - In DDS-I or DDS-II mode, there is no discernible difference
between this selection and Net. However, in TXP-I or TXP-II mode, this menu
selection initiates a BERT that does not interfere with the FDL (or other DTE port,
if active).

Table 3-6 Diagnostic Menu

Loop
Mode

BERT
Function

Local
Loop

Far V.54
Loop

V.54
Loop

DTE-A
Loop

DTE-B
Loop

Uni
Bi

BERT

Reset

Sync
Loss

Errored
Seconds

Bit Error

Time

Sync

Off
On

Off
On

Off
On

Off
On

Off
On

Off
Net
DTE A - Net
DTE A - DTE

DTE B - Net

*

DTE B -

DTE

*

Yes
No

display
only

display
only

display
only

HH:MM:SS
display only

In Sync (display only)
No Test (display only)

*

TDM mode only.

Advertising