Alarms

This status line shows the current network signal alarm state (Table 4-2) as
determined by the selectable thresholds set in the Alarm Configuration screen (see
page 42).

DTE

Alarms

This status line shows the selected element’s current DTE signal alarm state
(Table 4-3). DTE alarms are enabled or disabled through the DTE Port Parameters
screen (see page 39).

Loss of Signal

Seconds

The LOSS alarm displays, in the Current column, the consecutive seconds the unit
received signal has been interrupted. The Threshold column shows the value (in
seconds) that must be met or exceeded to generate an alarm. Setting the Threshold
value to 0 disables the alarm. Refer to Alarm Configuration on page 42 to set the
alarm parameters.

Out of Service

Seconds

The OOSS alarm displays, in the Current column, the consecutive seconds the unit
has received the out of service code. The Threshold column shows the value (in
seconds) that must be met or exceeded to generate an alarm. Setting the Threshold
value to 0 disables the alarm. Refer to Alarm Configuration on page 42 to set the
alarm parameters.

Out of Frame

Seconds

The OOFS alarm displays, in the Current column, the consecutive seconds the unit
received the out of frame code. The Threshold column shows the value (in
seconds) that must be met or exceeded to generate an alarm. Setting the Threshold
value to 0 disables the alarm. Refer to Alarm Configuration on page 42 to set the
alarm parameters.

FDL Errored

Seconds

The FDL alarm detects when the far-end unit encounters a problem even if the
DDS line are operating normally. FDL alarms only apply in TXP-I or TXP-II
modes and are ignored in the DDS-I, DDS-II, and any test loop or BERT mode.

Table 4-2 NET Alarm Indicators

Alarm

Description

None

No alarm threshold has been exceeded, although errors may exist that do not
exceed thresholds.

LOSS

The Loss Of Signal Seconds threshold is exceeded.

OOSS

The Out Of Service Seconds threshold is exceeded.

OOFS

The Out Of Frame Seconds threshold is exceeded.

FDL

The Facility Data Link threshold is exceeded.

Table 4-3 DTE Alarm Indicators

Alarm

Description

None

DTR on DTE interface is true, or the alarm has been disabled.

DTR A

DTR on indicated interface is false.

DTR B

DTR on indicated interface is false.