Ddsdtesendcode: (read-write), Ddsdteloopconfig: (read-write), Ddsdtestatus: (read-only) – Verilink PRISM 41TDM (34-00275.4) Product Manual User Manual

Page 69: Ddsdteinterfacetype: (read-only), Ddsdtev54loop: (read-write)

Advertising
background image

DDS 61

ddsDteStopBitNotAvail(3) - Stop bit information is not available. The DTE
interface is probably configured for synchronous operation.

ddsDteSendCode: (read-write)

Allows you to start or verify the setting of the DTE BERT. This variable describes
what type of test code is being sent from the DDS unit back towards the DTE.

ddsDteSendNoCode(1) - Normal data mode of operation

ddsDteSendOtherPattern(2) - Sending some other stress pattern than 511

ddsDteSend511Pattern(3) - Sending 511 stress pattern toward the DTE

ddsDteLoopConfig: (read-write)

Allows you to set a DTE loop or verify the status of a DTE loop

ddsDteNoLoop(1) - Normal data mode of operation

ddsDteV54Loop(2) - Data is looped back toward the DDS network and toward
the DTE loop activated via V.54 loop codes

ddsDteDataLoop(3) - Data is looped back toward the DTE loop activated via
data loop code received from the network

ddsDteOtherLoop(4) - DTE interface has some loop other than one of the
above listed loops active

ddsDteFarEndV54Loop(5) - The far end unit has a V.54 loop current on it's
DTE interface

ddsDteStatus: (read-only)

Reports the current operations status of the DTE interface

ddsDteNoAlarm(1) - DTE interface has no current alarms

ddsDteDtrAlarm(2) - DTE interface has currently declared a loss of DTR
alarm

ddsDteInterfaceType: (read-only)

Reports the DTE interface type being used

ddsDteInterfaceV35(1) - DTE interface is a V.35

ddsDteInterface232(2) - DTE interface is a RS232

ddsDteInterfaceOther(3) - DTE interface is something other than listed above

ddsDteInterfaceNotAvail(4) - DTE interface type is not available

ddsDteInterface530(5) - DTE interface is an EIA-530

ddsDteV54Loop: (read-write)

Allows you to select or verify the operational state of the V.54 option

ddsDteV54LoopEnabled(1) - The unit will currently respond to V.54 loop
codes