Ddsdtertsctsdelay: (read-write), Ddsdtertsstatus: (read-only), Ddsdtectsstatus: (read-only) – Verilink PRISM 41TDM (34-00275.4) Product Manual User Manual

Page 70: Ddsdtedcdstatus: (read-only), Ddsdtedtrstatus: (read-only), Ddsdtedsrstatus: (read- only), Ddsdtedsrcontrol: (read-write)

Advertising
background image

62

A

PPENDIX

A: SNMP A

GENT

ddsDteV54LoopDisabled(2) - The unit will not respond to V.54 loop codes

ddsDteRtsCtsDelay: (read-write)

Allows you to verify or select the delay used in the transition time on RTS and
CTS. For the PRISM 41TDM, only the ddsDteRtsCtsDelayNormal and
ddsDteRtsCtsDelayLong option are valid.

ddsDteRtsCtsDelayOff(1) - Delay is turned off

ddsDteRtsCtsDelayNormal(2) - Delay is a normal amount based on the data
rate and the hardware

ddsDteRtsCtsDelayLong(3) - Delay is generally doubled from the normal
delay

ddsDteRtsCTSDelayUserDefined(30) - Delay has been user defined to some
other value, when this value is set the delay is set to 30ms

ddsDteRtsStatus: (read-only)

Reports the current status of the RTS control lead

ddsDteRtsStatusHigh(1) - RTS control lead is in the active HIGH state

ddsDteRtsStatusLow(2) - RTS control lead is in the active LOW state

ddsDteCtsStatus: (read-only)

Reports the current status of the CTS control lead

ddsDteCtsStatusHigh(1) - CTS control lead is in the active HIGH state

ddsDteCtsStatusLow(2) - CTS control lead is in the active LOW state

ddsDteDcdStatus: (read-only)

Reports the current status of the DCD control lead

ddsDteDcdStatusHigh(1) - DCD control lead is in the active HIGH state

ddsDteDcdStatusLow(2) - DCD control lead is in the active LOW state

ddsDteDtrStatus: (read -only)

Reports the current status of the DTR control lead

ddsDteDtrStatusHigh(1) - DTR control lead is in the active HIGH state

ddsDteDtrStatusLow(2) - DTR control lead is in the active LOW state

ddsDteDsrStatus: (read- only)

Reports the current status of the DSR control lead

ddsDteDsrStatusHigh(1) - DSR control lead is in the active HIGH state

ddsDteDsrStatusLow(2) - DSR control lead is in the active LOW state

ddsDteDsrControl: (read-write)

Allows you to review and configure the DTE DSR lead (Circuit 107/CC)

Advertising