6620-3200

S210 – V.34 Symbol Rates (analogue)
The bits in this parameter control V.34 symbols rates and enables/disables V.34  
asymmetric rates. This parameter is used for diagnostic purposes only.

Bits 0 – 2 

Selects the range of allowed V.34 symbol rates.

Bit 

Symbol Rates (baud)

2 

1 

0 

0 

0 

0 

2 400 only

0 

0 

1 

2 400 only (no 2 734)

0 

1 

0 

2 400, 2 800

0 

1 

1 

2 400, 2 800, 3 000

1 

0 

0 

2 400, 2 800, 3 000, 3 200

1 

0 

1 

2 400, 2 800, 3 000, 3 200, 3 429 (default)

Bit 3 

Enable/disable V.34 asymmetric rates.

0 = Disable asymmetric rates

1 = Enable asymmetric rates (default)

Bits 4 – 7 Reserved.

Default: 13.

Table 1 S-registers

Short Form  Long Form 

Description 

Note

0 

OK  

A command line has been executed

1  

CONNECT <rn>

 Connection established 
( rn = call number of remote site)

2 

RING <rn>

Indicates an incoming call  (SETUP received)

3 

NO CARRIER <xx>

 No synchronization (xx = ISDN error cause)  
or if the the call was to an analogue destination. 
Replaces BUSY and NO DIALTONE.  
Dependent on ATXn setting. Also sent when  
the modem auto-disconnects due to loss of  
carrier.

4 

ERROR 

 Illegal command or error that can not be  
indicated otherwise e.g.  
1. The command line contains a syntax error.  
2.  The modem cannot execute a command  

contained in the command line, i.e., the  
command does not exist or is not  
supported. see register S93

3.   A command parameter within the command  

line is outside the permitted range.

5 

CONNECT  1 200 <rn>   A connection with a line speed of 1200 bit/s  

has been established.  
(V110 or analogue connection)

6 

NO  DIALTONE <xx>

No access to ISDN network (xx = ISDN error)

7 

BUSY<xx>

Number engaged (xx = ISDN error cause)