Westermo IDW-90 AT User Manual
Page 35

35
6620-3200
4.5 Sub addressing
With outgoing and incoming calls the transmission of subaddresses can be performed
using the ISDN supplementary service SUB. The subaddress is transmitted transparently
from the calling party to the called party before the B channel connection is fully estab-
lished.
Please note, that this ISDN service typically has to be enabled by the ISDN service pro-
vider and may be charged additionally.
The subaddress is separated by an “/” from the called number.
The functionality Subaddressing can be used with the dialling procedures AT-command
set, and automatic call.
Examples:
ATDisdnnumber[/subaddr]
isdnnumber
Dialling called party number
subaddr
Called subaddress
RING [<rn>[/subaddr]]
CONNECT [<rn>[/subaddr]]
rn
Calling party number
subaddr
Calling party subaddress
The calling subbaddress can be set up using the configuration commands subi and subo.
Note:- The subaddress can be entered additionally into all tables that contain
ISDN numbers for dialling or checking an ISDN address.
4.6 Automatic call establishment “Hotline” call
Automatic call establishment can be activated in three ways:
1. Initiated by an activation of the DTR control line (cmds= 6).
2. Initiated by activity of the Data line from DTE (cmds=7), autobauding is disabled
in this mode.
3. Initiated at power on reset, “always on” (cmds=8).
Autobauding is not supported when cmds is set to 6,7 or 8. Please select a baudrate
with DIP-switches or AT command. If autobauding is selected DTE baudrate will be
set to 9600 bit/s (br=4).
The status line DCD/DTR can be used to indicate a successful connection,
(see command cdcd and cdtr).
If a connection cannot be established successfully an automatic retry will be started.
The duration of trying to establish the connection and the pause for next retry can
be configured.
The dialled numbers are taken from the table catab, all numbers from the call table
catab will be taken one after each other. The parameter cato sets the timeout for estab-
lishing the call, capa the pause between call attempt and catry the number of retries.
The call can be disconnected through deactivating DTR see cdtr parameter, or through
using the inactivity timer idle.
To return to the AT- or Configurator command set the DIP-switches can be used SW3:5-
SW3:7.