*wiol – General IO list
This command is used to program the list of IO entries with parameters and data. 
The list can contain up to 10 entries

Syntax: 

 Set up a service entry: 
*WIOL=<entry>, <service>, <flag>, <timeout>, <priority>, <data1>,
<data2>, <data3>, <data4>, <data5>, <data6>

 Request the format string: 
*WIOL=? 
*WIOL : (1-10), (0-7),(0-3), (0-255), (0-1), (0-20 char),  
(0-160 char), (0-20 char), (0-2), (0-8 char), (0-20 char)

 List all table entries. Listing will pause every 3rd entry and wait 
for any key hit to continue. ESC will terminate.

 *WIOL? 
List entry 3. 
*WIOL=3?

<entry>

IO entry number, up to 10 entries can be defined.

<service>

IO entry service 

0=NONE 

No service defined for this entry

1=DIAL 

Makes a connection to the number defined in <data1>.

2=SMS 

<data1> Destination number of the SMS 
<data2> SMS-message 
<data3> SMS service provider number 
<data4> SMS protocol type (0=NONE, 1=UCP, 2=TAP) 
<data5> Password if required by provider.

3=TEXT 

 Make a connection to number defined in <data1> and transfer text defined in 
<data2>.

4=EMAIL 

Reserved for future use, service not implemented.

5=OUT 

 Make a connection to the number defined in <data1> and set/pulse the remote  
output according to pattern defined in string defined in <data2>.  
The connection is terminated after the pattern is transferred. 

6=CMD 

AT command specified by <data1> is executed when the entry is triggered.

7=TRANS 

 Makes a connection to number defined by <data1>, IO is transferred transparently 
between the two units. The transparent mode must be ended by a timeout.