6620-3200

 

0511/8511: 

D channel layer 1 status

 

0xF1 

Inactive not used

 

0xF2 

Sensing not used

 

0xF3 

Deactivate

 

0xF4 

Awaiting Signal

 

0xF5 

Identifying Input

 

0xF6 

Synchronized

 

0xF7 

Activated

 

0xF8 

Lost Framing

 

0512: 

D channel layer 1 C/I code (NT to TE)

 

0x00 

Deactivation Request from F7/F8

 

0x01 

Reset acknowledge

 

0x02 

Test mode acknowledge

 

0x03 

Slip detected

 

0x04 

Signal received

 

0x05 

Deactivation Request from F6

 

0x07 

Power up

 

0x08 

Activation request

 

0x0A 

Activation request loop

 

0x0B 

Illegal code violation

 

0x0C 

Activation indication priority 8

 

0x0D 

Activation indication priority 10

 

0x0E 

Activation indication loop

 

0x0F 

Deactivation confirmation

 

8512: 

D channel layer 1 C/I code (TE to NT)

 

0x00 

Timing

 

0x01 

Reset

 

0x02 

Test mode SSP

 

0x03 

Test mode SCP

 

0x08 

Activation request priority 8

 

0x09 

Activation request priority 10

 

0x0A 

Activation request loop

 

0x0F 

Deactivation indication