ACTi I91 User Manual

Page 14

Advertising
background image

www.acti.com


Hardware Manual

14

The table below shows the DI/DO connection specifications:

Device

DI

Connection design

TTL - compatible logic levels

Voltage

To trigger (low)

Logic level 0: 0V ~ 0.4V

Normal (high)

Logic level 1: 3.1V ~ 30V

Current

10mA ~ 100mA

DO

Connection design

Transistor (Open Collector)

Voltage & Current

< 24V DC, < 50mA

Typical Connection

Based on these specifications, if the DI device has a voltage of 0V ~ 30V or the DO device has

a voltage of < 24V (< 50mA), then the camera can supply internal power to these devices and

there is no need to connect the DI/DO device to an external power source.

In this case, use the

GND

and

DI1

pins to connect a DI device and use the

12V

and

DO1

pins

to connect a DO device. See wiring scheme below:

Consequently, to connect a second DI or DO device, use the GND and DI2 pins to connect a

second DI device, and the 12V and DO2 to connect a second DO device.