Waterproof solution with conduit, Waterproof solution, With conduit – ACTi KCM-7911 User Manual

Page 18: Hardware manual

Advertising
background image

www.acti.com


Hardware Manual

18

Waterproof Solution with Conduit

This section describes the procedures to waterproof the cabling connections using a flexible

conduit with 3/8” trade size (not supplied). This is the recommended solution when connecting

an external power adaptor, audio in/out, or digital input/output (DI/DO) devices to the camera.

1.

Disassemble the cable gland as shown below:

2.

Pull the Ethernet cable and other cables (if any) through the flex conduit.

NOTE:

To connect an external power adaptor, audio in/out, or digital input/output (DI/DO)

devices, insert the cables without connectors through the flex conduit together with the

Ethernet cable at this point.

3.

Insert the clamping nut through the flex conduit.

Lock

Nut

Body

(with Washer)

Sealing
Rubber

Clamping

Nut

Advertising