Allmand Brothers MAXI LITE II User Manual

Page 12

Advertising
background image

MAXI-LITE II

1-9

LIGHT PANEL

There are four lights on the Maxi-Lite II, therefore there
are four light switches.

For machines equipped with the LSC100 (option), Light
switches must be in the “On” position when the system
is set to “Auto.”

AUXILIARY POWER PANEL

The Main circuit breaker is located on the Auxiliary
Power Panel. The Main breaker protects all the AC lights
and outlets on the machine. It does not control the 12
Volt DC functions.

The Auxiliary circuit breaker(s), located on the Auxiliary
Power Panel, protects the 50 Amp outlet(s) located on
the right-rear panel of the machine, if the machine is so
equipped.

The 240 Volt single phase or 208 Volt three phase
outlets (if so equipped) are protected by circuit
breakers immediately above each outlet.

The 120 Volt Ground Fault Circuit Interrupter (GFCI)
outlets are duplex outlets. These are protected by push
button breakers. The upper breaker protects the left
side GFCI outlet and the lower breaker protects the
right side GFCI outlet.

1

Switches

Switch to turn lights on or off. The
switches also act as circuit
breakers for the lights.

LIGHTS

1

1

Main
breaker

Protects all of the AC lights and
outlets on the machine.

2

240/208V
outlets and
breakers

Outlets provide 240 V/208 V power.
The breakers protect the outlets
directly below them.

3

120V GFCI
outlets and
breakers

Outlets provide 120 V power, with
Ground Fault protection. The
push-button breakers protect the
outlets.

4

Auxiliary
breaker(s)

Protects the 50 A, 208 V outlet(s) on
the right side of the machine.

MAIN

AUXIILARY

1

2

4

3

Advertising
This manual is related to the following products: