2.6 Setting Dome Camera Protocol and Video

If a dome camera is to be installed with the keyboard controller, select the default protocol.

Consult service personnel if a dome camera is installed with device other than a keyboard
controller.

S2

You can set video type with DIP switch.

Select video type with D1 in S2.

You can set Protocol with DIP switch D2, D3 and D4 in S2.

S2

D2

D3

D4

P

ROTOCOL

OFF

OFF

OFF

F2, F2E, Pelco-P, Pelco-D : default

OFF OFF ON

F2, F2E

OFF

ON ON

Pelco-P, Pelco-D

You can set Baud Rate with DIP switch D5 and D6 in S2.

S2

D5

D6

B

AUD

R

ATE

OFF OFF

2400

bps

OFF

ON

4800 bps

ON

OFF

9600 bps : default

ON ON

19200 bps

Figure 5 – Video type, Protocol, Baud rate Selection Switches

2.7 Connections

• Connecting to the RS485

The dome camera can be controlled remotely by an external device or control system,
such as a control keyboard, using RS485 half-duplex serial communications signals.

• Connecting Video Output connector

Connect the video output (BNC) connector to the monitor or video input.

S2-D1

V

IDEO TYPE

OFF NTSC

ON

PAL

Advertising